MEASURING RANGES:
DC Voltage: 600mV/6V/60V/600V/1000V ±(0.5%+2)
AC Voltage: 6V / 60V / 600V / 750V ±(0.8%+3)
DC Current: 60 uA / 600 uA / 6 mA / 60 mA / 600 mA / 20 A ±(0.8%+8)
AC: 60 uA / 600 uA / 6 mA / 60 mA / 600 mA / 20 A ±(1%+12)
Resistance: 600 Ohm / 6 kOhm / 60 kOhm / 600 kOhm / 6 MOhm / 60 MOhm ±(0.8%+3)
Capacity: 6 nF /60 nF / 600 nF / 6 μF / 60 μF / 600 μF / 6 mF / 60 mF / 100 mF ±(3%+10)
Frequency: 9.999 Hz~9.999 MHz ±(1%+5)
Temperature: -40°C~1000°C; -40°C~1832°C ±(1%+5)
Measurement of the hFE of transistors
Diode test
Checking the continuity of the circuit
ADDITIONAL FEATURES:
NCV (Electric Field Detection Function)
Manual change of measuring ranges
True RMS
Fuse burnout notification
Anti-overload notification: >= 20 A
REL mode: reset reading
Freezing of the last indication
Backlighting the display
Record of maximum/minimum value
Sound-light signal: when measuring continuity and NCV
Auto Power Off
Low battery indicator
Maximum reading: 6000
GENERAL FEATURES:
Power supply: 2x 1.5V AAA battery
Display size: 56.5 x 36mm
Product dimensions: 183x88x56 mm
Weight: 346 g
WORKING ENVIRONMENT:
Operating Temperature: 0°C~40°C (32°F~104°F)
Storage Temperature: -10°C~ 50°C (14°F~122°F)
Relative Humidity: 0°C ~ 30°C =<75%, 30°C ~ 40°C =<50%
Working height: 0~2000 m
DC Voltage: 600mV/6V/60V/600V/1000V ±(0.5%+2)
AC Voltage: 6V / 60V / 600V / 750V ±(0.8%+3)
DC Current: 60 uA / 600 uA / 6 mA / 60 mA / 600 mA / 20 A ±(0.8%+8)
AC: 60 uA / 600 uA / 6 mA / 60 mA / 600 mA / 20 A ±(1%+12)
Resistance: 600 Ohm / 6 kOhm / 60 kOhm / 600 kOhm / 6 MOhm / 60 MOhm ±(0.8%+3)
Capacity: 6 nF /60 nF / 600 nF / 6 μF / 60 μF / 600 μF / 6 mF / 60 mF / 100 mF ±(3%+10)
Frequency: 9.999 Hz~9.999 MHz ±(1%+5)
Temperature: -40°C~1000°C; -40°C~1832°C ±(1%+5)
Measurement of the hFE of transistors
Diode test
Checking the continuity of the circuit
ADDITIONAL FEATURES:
NCV (Electric Field Detection Function)
Manual change of measuring ranges
True RMS
Fuse burnout notification
Anti-overload notification: >= 20 A
REL mode: reset reading
Freezing of the last indication
Backlighting the display
Record of maximum/minimum value
Sound-light signal: when measuring continuity and NCV
Auto Power Off
Low battery indicator
Maximum reading: 6000
GENERAL FEATURES:
Power supply: 2x 1.5V AAA battery
Display size: 56.5 x 36mm
Product dimensions: 183x88x56 mm
Weight: 346 g
WORKING ENVIRONMENT:
Operating Temperature: 0°C~40°C (32°F~104°F)
Storage Temperature: -10°C~ 50°C (14°F~122°F)
Relative Humidity: 0°C ~ 30°C =<75%, 30°C ~ 40°C =<50%
Working height: 0~2000 m