MEASURING RANGES LED indicator voltage measurement: • Ranges: 12 V / 24 V / 50 V / 120 V / 230 V / 400 V / 690 V • Accuracy: ±(1.5%+5) Phase sequence test: • Voltage: 100 ~ 690 V • Frequency: 50 ~ 60 Hz Single phase voltage detection: • Voltage: 100 ~ 690 V • Frequency: 50 ~ 400 Hz Circuit continuity test: • Resistance: 0 ~ 100 kOhm • Buzzer and LED indicator RCD test: • Voltage: 230 V • Frequency: 50~400 Hz Polarity detection: positive and negative ADDITIONAL FUNCTIONS Automatic change of measuring ranges Instrument test before measurement Freezing the last indication Low battery indicator Indicator exceeding voltage Automatic standby Backlight of the measuring point LCD screen GENERAL FEATURES IP65 Power supply: 2x 1.5 V (R03) Display size: 73.5 x 35.5 mm Dimensions: 272 x 85 x 31 mm Weight: 280 g Accessories: batteries
Universal meter (tester) UT18C
€47.60
Shipping from warehouse: D4
Estimated shipping: Wed, Nov 20 - Mon, Nov 25
14 days returnUnconditional return policy